Product description
The impact-resistant PVC electrical conduit 3/4 inch, roughly 19 mm, combines two things: a sturdier conduit that better withstands knocks, and more internal space than 5/8". That makes it the logical choice for a visible main run in a garage, shed or business premises, for example from a sub-distribution board to a row of sockets or to a workbench with several circuits. Because more wires fit through one 3/4" conduit, you need fewer parallel conduits on the wall, which makes the surface-mounted installation clearer. Use saddles and boxes that fit 19 mm and keep the bends wide, because otherwise pulling in the wires over long surface-mounted runs is difficult. If you work partly concealed and partly on the wall, you can switch to standard 3/4" conduit for the concealed section. Order this impact-resistant electrical conduit online from Houthandel Jan Sok; collect it from Celsius 10 in Meppel or have it delivered across the Netherlands.
Key features
- Impact-resistant: sturdier version that better withstands knocks.
- Size 3/4": outside diameter of approx. 19 mm.
- More internal space: several circuits or thicker wires in one conduit.
- For surface mounting: suitable for visible installation in a shed, garage or business premises.
- PVC: non-conductive and easy to work.
Applications
Suitable for, among other things:
- A visible main run from a sub-distribution board to a workstation.
- Surface-mounted installation in business premises, a stable or a barn.
- Several circuits along the same route in one conduit.
- Garages and workshops where conduit can be knocked.
Combine with
Finish the surface-mounted 3/4" installation with:
- Surface-mounted and junction boxes with entries for 3/4" conduit.
- Saddles or clips for 19 mm conduit.
- Bends and couplers in 3/4".
- Standard 3/4" conduit for concealed runs.
Installation
- Plan the route: mark out the route straight and level, with wide bends.
- Fixing points: drill and plug the saddles at regular intervals and at every box and bend.
- Cut to size: cut the conduit square and deburr the edge.
- Bend: use a bending spring for 3/4" or preformed bends.
- Finish the installation: clip the conduit into the saddles, connect it to the boxes and pull in the wires with a draw wire.
Product specifications
| Property | Value |
|---|---|
| Type | electrical conduit, impact-resistant version |
| Size | 3/4" (approx. 19 mm) |
| Material | PVC |
| Volume | 1 piece |
For beginners
Intermediate
This is a sturdy, slightly thicker electrical conduit for on the wall, with room for several wires. Ideal for a shed or garage. Use saddles and boxes for 3/4" (19 mm).
- Tools
- Conduit saw or PVC pipe cutter
- Bending spring for 3/4" conduit
- Spirit level and pencil
- Drill with masonry bit
- Draw wire
- Also needed
- pvc-elektra-installatiebuis-3-4
- pvc-elektra-installatiebuis-slagvast-5-8
- How to calculate
- You buy this per piece (per length of conduit).
- Common mistake
- Bends are often made too tight, so pulling the wire through on a long surface-mounted run gets stuck. Keep bends wide or use preformed bends.
Impact-resistant PVC electrical conduit 3/4"
Delivery and pickup
-
Pickup in Meppel: Free (ready after confirmation)
-
Truck delivery with a Moffett: €125 fixed delivery charge
-
Free delivery on orders from €2,500
Cut-to-size or custom-processed timber is non-returnable. Stock lengths: see returns policy.
Frequently asked questions
When do I use impact-resistant 3/4" electrical conduit?
For a visible surface-mounted installation where more wires need to go through one conduit, such as a main run in a garage, shed or business premises. The conduit is sturdier and has more internal space than 5/8".
Which saddles do I need for 3/4" electrical conduit?
Saddles or clips for 19 mm conduit. Saddles for 5/8" (16 mm) are too small.
Can I combine impact-resistant and standard 3/4" conduit?
Yes, the size is the same. For example, you use impact-resistant conduit for the visible part and standard conduit for the section you conceal in the wall.